Exit automatically after 15 seconds of no input.
Press and hold the SET key for more than 3 seconds until the first parameter code (F0) appears on the screen. Stc-600 Temperature Controller Manual Pdf
Defrost / Alarm Output (depending on specific model sub-variants). Exit automatically after 15 seconds of no input
Do not exceed 10A load. Use an external contactor for high-power devices (above 1000W). Do not exceed 10A load
[ STC-600 REAR TERMINALS ] +---+---+---+---+---+---+---+---+---+---+ | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10| +---+---+---+---+---+---+---+---+---+---+ \ / \ / \ / \ / \ / Power NTC Cooling Defrost Alarm/Fan Supply Sensor Relay Relay Relay : Power Supply Input (220VAC). Terminals 3 & 4 : NTC Temperature Sensor Probe input.
Used to enter the parameter menu and confirm settings.
: Connect your compressor, fan, or heater using the COM (Common) and NO (Normally Open) terminals. Troubleshooting and Status Indicators